REJUVENATE WIPES MATERIAL SAFETY DATA SHEET
SECTION 1. IDENTIFICATION
Product Name: Rejuvenate Ready to Use Wipes
Recommended Use: Hard surface disinfectant
Manufacturer/Supplier: Virox Technologies Inc., 2770 Coventry Rd., Oakville, ON, L6H 6R1, 905-813-0110
Identifier
Emergency Phone No. : Virox Technologies Inc., 1-800-387-7578
SDS No. : 000849
SECTION 2. HAZARDS IDENTIFICATION
Classification:
Not classified under any GHS hazard class.
Label Elements
Signal Word:
None
Hazard Statement(s):
None
Precautionary Statement(s)
– Prevention:
Wash hands thoroughly after handling. See section 8 for Individual Protective Measures Information.
– Response:
IF IN EYES: Get medical attention if symptoms appear. See section 4 First Aid Measures for Eye Contact.
– Storage:
No specific measures identified. See section 7 for Handling and Storage information.
– Disposal:
See section 13 for Waste Disposal information.
Other Hazards:
This product contains no substances which at their given concentration are considered to be hazardous to health.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Mixture:
Chemical Name | CAS No. | % | Other Identifiers |
---|---|---|---|
Hydrogen peroxide | 7722-84-1 | 0.5 |
Notes:
Active ingredients are listed above. All ingredients of this product are listed on the US EPA TSCA Inventory. EPA Reg. No. 74559-3
SECTION 4. FIRST-AID MEASURES
Skin Contact:
No specific first aid measures are required.
Eye Contact:
No specific first aid measures are required.
Inhalation:
No specific first aid measures are required.
Swallowing:
No specific first aid measures are required.
SECTION 5. FIRE-FIGHTING MEASURES
Extinguishable Media
– Suitable Extinguishing Media
Not combustible. Use extinguishing agent suitable for surrounding fire.
– Unsuitable Extinguishing Media
None known.
– Specific Hazards Arising from the Product
None known.
– Special Protective Equipment and Precautions for Fire-fighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions, Protective Equipment, and Emergency Procedures: Use the personal protective equipment recommended in Section 8 of this safety data sheet.
Environmental precautions: Review federal, provincial and local government requirements prior to disposal.
Methods and Materials for Containment and Cleaning Up: Never flush these wipes into toilets. Discard in solid waste bin. Towelettes contaminated with blood or body fluids should be disposed of according to federal, state, and local regulations for infectious waste disposal.
SECTION 7. HANDLING AND STORAGE
Precautions for Safe Handling: Use good industrial hygiene practices in handling this material. FOR COMMERCIAL AND INDUSTRIAL USE ONLY.
Conditions for Safe Storage: Store in an area that is out of direct sunlight. Avoid storage at elevated temperatures. KEEP OUT OF REACH OF CHILDREN.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
ACGIH TLV® | OSHA PEL | AIHA WEEL | |
---|---|---|---|
Chemical Name | TWA | STEL | TWA | Ceiling | 8 hour TWA | STEL |
Hydrogen peroxide | 1 ppm | 1 ppm |
Appropriate Engineering Controls:
No specific ventilation requirements.
Individual Protection Measures:
– Eye/Face Protection:
Not required if product is used as directed.
– Skin Protection:
Not required if product is used as directed.
– Respiratory Protection
Not required if product is used as directed.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Clear colourless liquid saturated on wipes
Odor: Faint, characteristic odor
Odor Threshold: Not available
pH: 2.5 – 3.5
Melting Point/Freezing Point: Not available (melting); Not available (freezing)
Initial Boiling Point/Range: Not available
Flash Point: > 199 ºF (93 ºC)
Evaporation Rate: Not available
Flammability (solid, gas): Not applicable
Upper/Lower Flammability or Explosive Limit: Not available (upper); Not available (lower)
Vapour Pressure: Not available
Relative Density: (water = 1) 1.01 at 68 ºF (20 ºC)
Solubility: Soluble in water
Partition Coefficient: Not available
n-Octanol/Water (Log Kow)
Auto-ignition Temperature: Not available
Decomposition Temperature: Not available
Viscosity: 1.122 centistokes at 68 ºF (20 ºC) (kinematic); Not available (dynamic)
Other Information
Physical State: Wet wipes
Critical Temperature: Not available %
Volatile: 0.0%
SECTION 10. STABILITY AND REACTIVITY
Reactivity: Not reactive.
Chemical Stability: This product is stable.
Possibility of Hazardous Reactions: Hazardous polymerization will not occur.
Conditions to avoid: High temperatures. Refer to incompatible materials.
Incompatible Materials: Do not mix with concentrated bleach products.
Hazardous Decomposition Products: None known.
SECTION 11. TOXICOLOGICAL INFORMATION
Likely Routes of Exposure:
Inhalation; skin contact; eye contact; ingestion.
Acute Toxicity:
LC50 (Inhalation): 117.3mg/L
LD50 (Oral): >5000mg/kg
LD50 (Dermal): > 5050mg/kg
Skin Corrosion/Irritation:
Not classified under GHS criteria.
Serious Eye Damage/Irritation:
Not classified under GHS criteria
STOT (Specific Target Organ Toxicity) – Single Exposure
– Inhalation
Not classified under GHS criteria.
– Skin Absorption
Not classified under GHS criteria.
– Ingestion
Not classified under GHS criteria
STOT (Specific Target Organ Toxicity) – Repeated Exposure:
Not classified under GHS criteria.
Respiratory and/or Skin Sensitization:
Not a respiratory sensitizer. Not a skin sensitizer.
Carcinogenicity:
Not classified under GHS criteria.
Reproductive Toxicity:
– Development of Offspring:
Not classified under GHS criteria.
– Sexual Function and Fertility:
Not classified under GHS criteria.
– Effects on or via Lactation:
Not classified under GHS criteria.
Germ Cell Mutagenicity:
Not classified under GHS criteria.
Interactive Effects:
None known.
SECTION 12. ECOLOGICAL INFORMATION (non-mandatory)
This section is not required by OSHA HCS 2012.
SECTION 13. DISPOSAL CONSIDERATIONS (non-mandatory)
Disposal Methods:
Review the STORAGE and DISPOSAL instructions on product label prior to disposal
SECTION 14. TRANSPORT INFORMATION (non-mandatory)
Not regulated under Canadian TDG regulations. Not regulated under US DOT Regulations.
Special Precautions – Not applicable
Transport in Bulk According to Annex II of MARPOL 73/78 and the IBC Code
Not applicable
IMO/IMDG Classification
Not Regulated.
SECTION 15. REGULATORY INFORMATION (non-mandatory)
Safety, Health and Environmental Regulations
USA
Toxic Substances Control Act (TSCA) Section 8(b)
All ingredients are on the TSCA Inventory or are exempt from TSCA Inventory requirements under 40 CFR 720
Additional USA Regulatory Lists
U.S. Regulations
EPA Reg. No.: 74559-3
This chemical is a pesticide product registered by the U.S. Environmental Protection Agency and is subject to certain labelling requirements under federal pesticide law. These requirements differ from the classification criteria and hazard information required for safety data sheets (SDS) and for workplace labels for non-pesticide chemicals. The following is the hazard information as required on the pesticide label: KEEP OUT OF REACH OF CHILDERN.
California Proposition 65
This product is not subject to the reporting requirements under California’s Proposition 65.
Other U.S. Federal Regulations
SARA 302/304/311/312 extremely hazardous substances: No listed substance.
SARA 302/304 emergency planning and notification: No listed substance.
SECTION 16. OTHER INFORMATION
HMIS Rating
Health – 0
Flammability – 0
Physical Hazard – 0
SDS Prepared By Virox Technologies Inc.
Phone No. – (800) 387-7578
Date of Preparation – February 27, 2017
Date of Last Revision – May 15, 2020
As always if you have any questions about this process or anything else please feel free to contact us and take advantage of our “FREE TECH SUPPORT.”
We also offer FREE VIRTUAL TECH SUPPORT to “See and Talk” with a “Real Time Live Technician” for any problems you may be in need of help with.
You can also use our “FREE MAINTENANCE PROGRAM”. Take the guesswork and worrying about what unit is due for maintenance and which maintenance cycle it is time for. We will keep track of all your autoclaves and let you know when it’s time for anything.