Steris Autoclaves
Showing all 2 results
-
Autoclaves, Steris, Steris Autoclaves
Refurbished Steris Amsco Model V116 Steam Sterilizer
This Steris V116 Steam Sterilizer is designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer.
Steris Amsco Model V116 Specifications Include:
- Chamber Size: 16″ x 16″ x 26” (406mm x 406mm x 660mm)
- Chamber Volume – 29 gallons (110 Liters)
- Overall Exterior Dimensions (including door lock-wheel with door closed): 74.5″H x 30″W x 35.75″D (189.2mm x 76.2mm x 90.8mm)
- Operating Temperature: 250ºF to 270ºF (121ºC to 132ºC)
- One (1) Rack, Two (2) Shelves
- Touch Screen Display
Cycles Include:
- Pre-Vac
- Gravity
- Flash
- Express
- Leak Test
- Daily Air Removal
Call 704-966-1650 option 1 for additional options, installation and de-installation, annual maintenance services and repairs (yes, we do that too)!
You can also – Visit our Steris Service Solutions Page here →
SKU: Steris Amsco Model V116 Steam Sterilizer -
Autoclaves, Steris, Steris Autoclaves
Refurbished Steris Amsco Model V120 Steam Sterilizer
This Steris V116 Steam Sterilizer is designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer.
Steris Amsco Model V120 Specifications Include:
- Chamber Size: 20″ x 20″ x 38” (508mm x 508mm x 965mm)
- Chamber Volume – 66 gallons (250 Liters)
- Overall Exterior Dimensions (including door lock-wheel with door closed): 74.5″H x 30″W x 45.125″D (189.2mm x 76.2mm x 114.6mm)
- Operating Temperature: 250ºF to 270ºF (121ºC to 132ºC)
- One (1) Rack, Two (2) Shelves
- Touch Screen Display
Cycles Include:
- Pre-Vac
- Gravity
- Flash
- Express
- Leak Test
- Daily Air Removal
Call 704-966-1650 option 1 for additional options, installation and de-installation, annual maintenance services and repairs (yes, we do that too)!
You can also – Visit our Steris Service Solutions Page here →
SKU: Steris Amsco Model V120 Steam Sterilizer
Statim USA provides high-performance STERIS autoclaves and steam sterilizers designed to meet the rigorous demands of modern healthcare environments, including operating rooms (OR) and sterile processing departments (SPD). Our selection features both new and expertly refurbished units from the renowned AMSCO® Century® Series, known for their reliability, speed, and advanced infection control capabilities.
These sterilizers are engineered with a focus on workflow efficiency, featuring vertical sliding doors for hands-free operation and touchscreen control systems that simplify cycle selection. Whether you need a compact solution for heat-stable materials or a high-capacity floor-mounted unit, our STERIS range ensures patient safety through validated sterilization cycles that meet AAMI standards.
Features Include:
- Intuitive Controls: Easy-to-read touchscreen displays with real-time status readouts and built-in help screens for troubleshooting.
- Enhanced Reliability: Units feature modular piping, non-lubricated steam-activated door seals, and electronic water conservation systems to reduce long-term maintenance costs.
- Flexible Configurations: Available in various chamber sizes with options for built-in steam generators or house-steam connections.
FAQ
Q: What are the primary differences in chamber size between the V116 and V120 models?
A: The STERIS Century V116 features a compact 16″ x 16″ x 26″ (110 Liters) chamber, ideal for smaller surgical centers or satellite ORs. The STERIS Century V120 offers a larger 20″ x 20″ x 38″ (250 Liters) chamber, providing significantly more space for high-volume instrument processing.
Q: What sterilization cycles are available on these Century Series units?
A: Both the V116 and V120 pre-vacuum models are equipped with a full suite of cycles, including Pre-vac, Gravity, Flash, Express, Leak Test, and Daily Air Removal (DART). These cycles are validated to AAMI standard ST-8 to ensure consistent performance.
Q: What are the utility requirements for installing a V116 or V120 autoclave?
A: These sterilizers typically require a 120V, 50/60 Hz electrical connection for controls and a steam supply between 50 to 80 psig. If building-supplied “house steam” is unavailable, both models can be equipped with an optional built-in electric steam generator.
To explore our current inventory of STERIS Century V116 and V120 units, visit the Sterilizer Autoclave Solutions Steris Autoclaves page or contact our specialists for a custom quote at 704-966-1650.